Capacity : 200 RT X 3 Water Cooled Screw Chillers
Drive System: Variable Speed Drive (VSD) For Energy Saving with Environmentally Friendly Refrigerant 134a.
Energy Saving :
A chiller is the highest power-hungry machine in a commercial building that can deliver cooling load as low as 10% to 90% saving a huge amount of energy as per the demand of the system by using variable speed drives
Microprocessor based 32 Bit direct digital controllers are used to monitor and control the HVAC System.
All pumps, cooling towers, AHUs, ventilation fans are VSD driven meant for efficient operation and energy saving
High quality indoor air is maintained by special air filter known as Medium Filter as part of IAQ (Indoor Air Quality) which is continuously monitored
There is pre-set or Adjustable VAV diffuser in every location for the comfort cooling of an individual area.
International Certification: AHRI, AHRI Standard 560/590
Description: Intelligent fire detection system with smoke and heat detectors with enunciator panel to pinpoint location of smoke or fire, enabling swift action to extinguish and fight fire.
International Certification: UL Listed & FM Approved
Fire Pump : Patterson
Jockey Pump : Patterson
Automatic Sprinkler : Tyco
Capacity : 750 GPM (FP) + 30 GPM (JP)
Description :
Automatic sprinkler & fire hydrant system which is run by diesel fire pump and supported with Electric Jockey Pump.
A dedicated fire water tank capacity of 1,45,000 Liter
Provision for city Fire Brigade connection
Fire barriers and fire rated doors are used to prevent smoke from spreading across different floors
International Certification: UL Listed & FM Approved
Application of rainwater harvesting in urban water system provides a substantial benefit for both water supply and wastewater subsystems by reducing the need for clean water in the water distribution system as well as less generated storm water in sewer system.
This harvested rainwater is used in the water of the central air-conditioning system and also taken into the system water recycling system for other applications like toilet flush, gardening etc.
All the water faucets are LEED compliant, preventing water wastage when a faucet is used
All the toilet flush units (WC) are LEED compliant to flush a measured quantity of water i.e. 3.8 liter per flush thus saving water compared to conventional flush system.
The building has background music through PA system
Transformer Capacity : 1600 KVA
Automatic Voltage Regulator (AVR): This AVR facilitates stable voltage supply to the building, saving all electrical equipment from any damage from the supply voltage fluctuation
Bus Bar Trunking System (BBT): Bus Bar Trunking System has significant advantages over cable, such as improved electrical performance, reliable electricity distribution scheme, speed installation, flexibility and transformability of the system, various kinds of high degree of protection, ease of maintenance and energy savings in operation.
A tenant can save up to 30% power in this building compared to any other conventional buildings
International Certification / Standard: DIN, IEEE STD C57.02.01, EN 60076-11, UL Listed, CSA & TUV
Capacity : 725 KVA X 3 Nos, And 275 KVA X 1 Nos
Mains Backup : Full Power Backup
Description :
Auto power transfer
3 NAdyaos of generators auto synchronized
7-8 hours continuous duty operation
Electronic Woodward Governor for better fuel economy.
The diesel generator room is acoustically treated by world famous company “mason acoustics” for quiet operation
International Standard / Certification: CE, NEMA, ISO
We have a 100% waste water recycling plant that allows us to conserve water throughout the year
Sewage treatment plant, waste water treatment plant, and water re-cycling system are used to optimize the use of water.
We continuously re-cycle waste water & rain harvested water to full utilization in toilet flush, cooling tower make up water for the central air conditioning system, and gardening.
100% Sewage treatment plant water are optimize re-cycling system.
We have 1000 feet deep tube well that pumps high-quality water that is further treated in a water treatment plant (WTP).
We use solar power to heat water in our efficient water heater for use in bathrooms and ablution round the year
The operating software is “Honeywell enterprise building integrator”
Microprocessor-based controllers are true standalone of networked configurable features.
Multiple operator interface options.
Preserve the controller database for an unlimited period of time.
Integrated features: tenant billing, web access, lighting control, security/cc tv/fire protection & detection
The BMS system makes this building energy efficient and intelligent
International certification: UL listed and back net listed
No. Of lifts : 3 passenger & 1 service lift
Speed : high speed lift 2.5 m/sec.
Interior finish : hairline stainless steel wall finish with a large mirror and 3 side SS continuous handle
Safety features : there are at least 20 safety features to protect and evacuate the passengers from the cabin
Capacity : passenger lifts- 1150kgs. (17 persons) service lifts- 1275kgs. (17 persons)
Drive control system : AC – variable voltage variable frequency (VVVF) control gearless drive system.
Operation : three car group control: single car selective collective control system for service lift.
International standards : machine room less: EN 81-1: machine room system: Mitsubishi electric standard
We have high-quality mineral water grade drinking water from our own plant
This water is distributed to all the floors 24/7, saving energy bill and providing everyone with clean drinking water
We have highly automated parking with paging facility ST's ramp, driveway and car parking areas surface coating system
Finished with Flow Crete’s (polyurethane) Decksheild ID and (polyurethane) flow fresh MF for M & E areas
We also have colored smooth & bright seamless high abrasion resistant finish which has the green label
Damp resistant and noise minimizing coating surfaces